1. After disassembling the defective sample 2, it is found that there is colloid on the needle shaft
2. Observe the spring and needle, no abnormality.
Summarize:
1. The reason for the shrinkage of the needle and the stuck pin of the defective sample 1 is that the nozzle is blocked by solid glue, which causes the needle shaft to be unable to be pressed normally.
2. The reason why the bad sample 2 is stuck is that the nozzle is blocked by the colloid, resulting in the stuck pin.
3. There is no process environment with glue in our production riveting process.
Suggestion: The client analyzes the process of the spring-type guide needle, and pays attention to the control of the process with glue to prevent the glue from contacting the PogoPin.